FDI05M Forced Entry Resistant Door System

Features

  • Designed to Meet 5 Minute Forced Entry Protection
  • Continuous Hinge Preparation
  • Heavy Duty 11-Gauge Steel Construction
  • Door and Frame Shipped as Complete Unit
  • Single Vision, Double Vision, Opaque


DOS Codes & Model Numbers:

w/Vision

  • DOS 1141 GDT-05N-FDI-01

Opaque

  • DOS 2141 GDO-05N-FDI-01


Product Description

The FDI05M Forced Entry Resisting Door System is designed to provide 5 minutes of forced entry protection from a variety of tools.

Basic Use

Use this door system to provide protection in those applications where a forced entry threat exists. It is recommended that this door be used in conjunction with protected wall areas.

Limitations

This door has been designed to meet the 5-minute forced entry requirements as set forth in DOS SD-STD-01.01, Rev.G (amended). It is recommended that each end user determine the forced entry threat and choose the correct product to meet and resist that threat.

Construction

Doors and frames are constructed of 11-gauge steel components welded together. Each door will have 11 gauge vertical and horizontal steel stiffeners. Top and bottom of door are flush with face sheets.

Specifications

Door construction: Doors are constructed of steel plates, and steel tubes 1 ฝ” thick.

Door Frame Construction: Door frame assembly is constructed of steel tubes. Framing dimensions are 2” wide x 5” deep. Door frames are completely fabricated at factory and shipped with doors attached. All doors are pre-tested for all locking functions, clearances, and ease of operation, to ease field installation. All joint connections are welded to provide a rigid assembly when installed. The doorstop is built into the frame. Frames are predrilled to accept ฝ” anchors 12” on center. Shims are provided to take up a space at each anchor. Wiring diagrams are shipped enclosed in the hardware packages.

Hardware Assembly: Each door is equipped as follows:

  1. Door Closer (LCN 4041 CUSH)
  2. (2) Forced Entry Locks (Adams Rite 1850S w/ 15tt Thumbturns)
  3. Continuous Hinge (Roton 780112HD)
  4. Aluminum Threshold (Pemko 177AV36)
  5. Weather Stripping (Pemko SS88D17)

Optional Hardware: Refer to the SHW group page for additional hardware information. You must select a lockset, pull handle, or panic device that suits your application. Most hardware is shipped pre-assembled with the door unit.

Subframes: To meet forced entry requirements of DOS SD.STD-01.01 (Rev. G amended), steel tube subframes ผ” wall thickness minimum, must be attached to concrete or masonry with Hiltiฎ Epoxy Anchoring System. An acceptable alternative is the use of steel embeds, ฝ” thick minimum. These systems are included as options in our product line.

Finish: All doors and frames are furnished prime painted, ready for final finish in field. Options: Factory can apply polyurethane enamel; link to color chart is available on the main page. Doors can also be fitted with various types of architectural metals.

Glazing: Glazing materials shall be of a type approved by H.P. White Laboratory, Inc. for forced-entry resistance. Size to be limited to 20” x 30” vision area. Glazing is replaceable without removing the door from the frame.

Applicable Standard

ท DOS SD.STD-01.01 (Rev. G amended)

 

Weights and Measurements

Standard Door:

Door Thickness: 1 พ”

Frame Thickness: 2” x 5”

Door Size: 36” x 84”

Frame Size: 40” x 86”

Rough Opening: 40 ฝ” x 86 ผ”

Shipping Weight: ~1110 lbs