The FDI05M Forced Entry Resisting
Door System is designed to provide 5 minutes of forced entry protection from a
variety of tools.
Basic Use
Use this door system to provide protection in those applications where a
forced entry threat exists. It is recommended that this door be used in
conjunction with protected wall areas.
Limitations
This door has been designed to meet the 5-minute forced entry requirements as
set forth in DOS SD-STD-01.01, Rev.G (amended). It is recommended that each end
user determine the forced entry threat and choose the correct product to meet
and resist that threat.
Construction
Doors and frames are constructed of 11-gauge steel components welded
together. Each door will have 11 gauge vertical and horizontal steel stiffeners.
Top and bottom of door are flush with face sheets.
Specifications
Door construction:
Doors are constructed of steel plates, and steel tubes 1 ฝ thick.
Door Frame Construction:
Door frame assembly is constructed of steel tubes. Framing dimensions are 2
wide x 5 deep. Door frames are completely fabricated at factory and shipped
with doors attached. All doors are pre-tested for all locking functions,
clearances, and ease of operation, to ease field installation. All joint
connections are welded to provide a rigid assembly when installed. The doorstop
is built into the frame. Frames are predrilled to accept ฝ anchors 12 on
center. Shims are provided to take up a space at each anchor. Wiring diagrams
are shipped enclosed in the hardware packages.
Hardware Assembly:
Each door is equipped as follows:
- Door
Closer (LCN 4041 CUSH)
- (2)
Forced Entry Locks (Adams Rite 1850S w/ 15tt Thumbturns)
- Continuous Hinge (Roton 780112HD)
- Aluminum Threshold (Pemko 177AV36)
- Weather Stripping (Pemko SS88D17)
Optional Hardware: Refer to the
SHW group page for
additional hardware information. You must select a lockset, pull handle, or
panic device that suits your application. Most hardware is shipped pre-assembled
with the door unit.
Subframes: To meet forced entry requirements of DOS SD.STD-01.01 (Rev. G
amended), steel tube subframes ผ wall thickness minimum, must be attached to
concrete or masonry with Hiltiฎ Epoxy Anchoring System. An acceptable
alternative is the use of steel embeds, ฝ thick minimum. These systems are
included as options in our product line.
Finish: All doors and frames are furnished prime painted, ready for final
finish in field. Options: Factory can apply polyurethane enamel; link to color chart is available on the main page. Doors can also be fitted with various types of
architectural metals.
Glazing: Glazing materials shall be of a type approved by H.P. White
Laboratory, Inc. for forced-entry resistance. Size to be limited to 20 x 30
vision area. Glazing is replaceable without removing the door from the frame.
Applicable Standard
ท DOS SD.STD-01.01 (Rev. G amended)
Weights and Measurements
Standard Door:
Door Thickness: 1 พ
Frame Thickness: 2 x 5
Door Size: 36 x 84
Frame Size: 40 x 86
Rough Opening: 40 ฝ x 86 ผ
Shipping Weight: ~1110 lbs
|